関連情報 線量評価モデルのデータ(NORM一般公衆) |
|
|
|
|
環境パラメータ(RP-122) |
|
|
|
|
|
シナリオ |
NORMタイプ |
|
age |
exposure time h/a |
density kg/m3 |
dilution |
breathing rate m3/h |
dust concentration g/m3 |
direct ingestion g/h |
備考 |
Playground |
岩石 |
Rock |
0-1 |
500 |
2000 |
1 |
0.12 |
0.0005 |
0 |
plane, 10cm thickness |
Playground |
岩石 |
Rock |
1-2 |
500 |
2000 |
1 |
0.22 |
0.0005 |
0.01 |
plane, 10cm thickness |
Playground |
岩石 |
Rock |
2-7 |
500 |
2000 |
1 |
0.36 |
0.0005 |
0.01 |
plane, 10cm thickness |
Playground |
岩石 |
Rock |
7-12 |
500 |
2000 |
1 |
0.64 |
0.0005 |
0.005 |
plane, 10cm thickness |
Playground |
岩石 |
Rock |
12-17 |
500 |
2000 |
1 |
0.84 |
0.0005 |
0.005 |
plane, 10cm thickness |
Playground |
岩石 |
Rock |
>17 |
500 |
2000 |
1 |
0.925 |
0.0005 |
0.005 |
plane, 10cm thickness |
Playground |
灰 |
Ash |
0-1 |
500 |
2000 |
0.1 |
0.12 |
0.0005 |
0 |
plane, 10cm thickness |
Playground |
灰 |
Ash |
1-2 |
500 |
2000 |
0.1 |
0.22 |
0.0005 |
0.01 |
plane, 10cm thickness |
Playground |
灰 |
Ash |
2-7 |
500 |
2000 |
0.1 |
0.36 |
0.0005 |
0.01 |
plane, 10cm thickness |
Playground |
灰 |
Ash |
7-12 |
500 |
2000 |
0.1 |
0.64 |
0.0005 |
0.005 |
plane, 10cm thickness |
Playground |
灰 |
Ash |
12-17 |
500 |
2000 |
0.1 |
0.84 |
0.0005 |
0.005 |
plane, 10cm thickness |
Playground |
灰 |
Ash |
>17 |
500 |
2000 |
0.1 |
0.925 |
0.0005 |
0.005 |
plane, 10cm thickness |
Playground |
砂 |
Sand |
0-1 |
500 |
2000 |
1 |
0.12 |
0.0005 |
0 |
plane, 10cm thickness |
Playground |
砂 |
Sand |
1-2 |
500 |
2000 |
1 |
0.22 |
0.0005 |
0.01 |
plane, 10cm thickness |
Playground |
砂 |
Sand |
2-7 |
500 |
2000 |
1 |
0.36 |
0.0005 |
0.01 |
plane, 10cm thickness |
Playground |
砂 |
Sand |
7-12 |
500 |
2000 |
1 |
0.64 |
0.0005 |
0.005 |
plane, 10cm thickness |
Playground |
砂 |
Sand |
12-17 |
500 |
2000 |
1 |
0.84 |
0.0005 |
0.005 |
plane, 10cm thickness |
Playground |
砂 |
Sand |
>17 |
500 |
2000 |
1 |
0.925 |
0.0005 |
0.005 |
plane, 10cm thickness |
Playground |
スラグ |
Slag |
0-1 |
500 |
2000 |
1 |
0.12 |
0.0005 |
0 |
plane, 10cm thickness |
Playground |
スラグ |
Slag |
1-2 |
500 |
2000 |
1 |
0.22 |
0.0005 |
0.01 |
plane, 10cm thickness |
Playground |
スラグ |
Slag |
2-7 |
500 |
2000 |
1 |
0.36 |
0.0005 |
0.01 |
plane, 10cm thickness |
Playground |
スラグ |
Slag |
7-12 |
500 |
2000 |
1 |
0.64 |
0.0005 |
0.005 |
plane, 10cm thickness |
Playground |
スラグ |
Slag |
12-17 |
500 |
2000 |
1 |
0.84 |
0.0005 |
0.005 |
plane, 10cm thickness |
Playground |
スラグ |
Slag |
>17 |
500 |
2000 |
1 |
0.925 |
0.0005 |
0.005 |
plane, 10cm thickness |
Building (walls of NORM) |
岩石 |
Rock |
|
7000 |
2300 |
0.3 |
|
|
|
floor, ceiling, 2 walls(3x4 m2), 20cm wall thickness, 2.5 m height |
Building (walls of NORM) |
灰 |
Ash |
|
7000 |
2300 |
0.1 |
|
|
|
floor, ceiling, 2 walls(3x4 m2), 20cm wall thickness, 2.5 m height |
Building (walls of NORM) |
砂 |
Sand |
|
7000 |
2300 |
0.3 |
|
|
|
floor, ceiling, 2 walls(3x4 m2), 20cm wall thickness, 2.5 m height |
Building (walls of NORM) |
スラグ |
Slag |
|
7000 |
2300 |
0.3 |
|
|
|
floor, ceiling, 2 walls(3x4 m2), 20cm wall thickness, 2.5 m height |
|
|
|
|
|
|
external 線量換算係数(RP-122) |
|
|
|
|
|
核種 |
単位 |
Scenario |
線量換算 |
Ac 227+ |
(Sv/h)/(kBq/kg)) |
Playground |
7.93E-08 |
Ac 227+ |
(Sv/h)/(kBq/kg)) |
Outdoors, Heap-20 m |
9.93E-09 |
Ac 227+ |
(Sv/h)/(kBq/kg)) |
Indoors, Heap-25 m |
1.85E-10 |
Ac 227+ |
(Sv/h)/(kBq/kg)) |
Outdoors, on heap 1 m |
9.02E-08 |
Ac 227+ |
(Sv/h)/(kBq/kg)) |
House #1, indoors |
9.97E-08 |
Ac 227+ |
(Sv/h)/(kBq/kg)) |
House #2, indoors |
1.28E-08 |
K 40 |
(Sv/h)/(kBq/kg)) |
Playground |
2.77E-08 |
K 40 |
(Sv/h)/(kBq/kg)) |
Outdoors, Heap-20 m |
4.95E-09 |
K 40 |
(Sv/h)/(kBq/kg)) |
Indoors, Heap-25 m |
4.90E-10 |
K 40 |
(Sv/h)/(kBq/kg)) |
Outdoors, on heap 1 m |
3.77E-08 |
K 40 |
(Sv/h)/(kBq/kg)) |
House #1, indoors |
5.13E-08 |
K 40 |
(Sv/h)/(kBq/kg)) |
House #2, indoors |
4.49E-09 |
Pa 231 |
(Sv/h)/(kBq/kg)) |
Playground |
6.02E-09 |
Pa 231 |
(Sv/h)/(kBq/kg)) |
Outdoors, Heap-20 m |
7.34E-10 |
Pa 231 |
(Sv/h)/(kBq/kg)) |
Indoors, Heap-25 m |
9.95E-12 |
Pa 231 |
(Sv/h)/(kBq/kg)) |
Outdoors, on heap 1 m |
6.86E-09 |
Pa 231 |
(Sv/h)/(kBq/kg)) |
House #1, indoors |
7.52E-09 |
Pa 231 |
(Sv/h)/(kBq/kg)) |
House #2, indoors |
9.48E-10 |
Pb 210+ |
(Sv/h)/(kBq/kg)) |
Playground |
1.07E-10 |
Pb 210+ |
(Sv/h)/(kBq/kg)) |
Outdoors, Heap-20 m |
1.02E-11 |
Pb 210+ |
(Sv/h)/(kBq/kg)) |
Indoors, Heap-25 m |
1.01E-20 |
Pb 210+ |
(Sv/h)/(kBq/kg)) |
Outdoors, on heap 1 m |
1.07E-10 |
Pb 210+ |
(Sv/h)/(kBq/kg)) |
House #1, indoors |
8.78E-11 |
Pb 210+ |
(Sv/h)/(kBq/kg)) |
House #2, indoors |
4.01E-11 |
Po 210 |
(Sv/h)/(kBq/kg)) |
Playground |
1.66E-12 |
Po 210 |
(Sv/h)/(kBq/kg)) |
Outdoors, Heap-20 m |
2.53E-13 |
Po 210 |
(Sv/h)/(kBq/kg)) |
Indoors, Heap-25 m |
1.39E-14 |
Po 210 |
(Sv/h)/(kBq/kg)) |
Outdoors, on heap 1 m |
2.07E-12 |
Po 210 |
(Sv/h)/(kBq/kg)) |
House #1, indoors |
2.69E-12 |
Po 210 |
(Sv/h)/(kBq/kg)) |
House #2, indoors |
2.63E-13 |
Ra 226+ |
(Sv/h)/(kBq/kg)) |
Playground |
3.25E-07 |
Ra 226+ |
(Sv/h)/(kBq/kg)) |
Outdoors, Heap-20 m |
5.37E-08 |
Ra 226+ |
(Sv/h)/(kBq/kg)) |
Indoors, Heap-25 m |
4.43E-09 |
Ra 226+ |
(Sv/h)/(kBq/kg)) |
Outdoors, on heap 1 m |
4.20E-07 |
Ra 226+ |
(Sv/h)/(kBq/kg)) |
House #1, indoors |
5.55E-07 |
Ra 226+ |
(Sv/h)/(kBq/kg)) |
House #2, indoors |
5.17E-08 |
Ra 228+ |
(Sv/h)/(kBq/kg)) |
Playground |
1.78E-07 |
Ra 228+ |
(Sv/h)/(kBq/kg)) |
Outdoors, Heap-20 m |
2.84E-08 |
Ra 228+ |
(Sv/h)/(kBq/kg)) |
Indoors, Heap-25 m |
1.91E-09 |
Ra 228+ |
(Sv/h)/(kBq/kg)) |
Outdoors, on heap 1 m |
2.27E-07 |
Ra 228+ |
(Sv/h)/(kBq/kg)) |
House #1, indoors |
2.98E-07 |
Ra 228+ |
(Sv/h)/(kBq/kg)) |
House #2, indoors |
2.86E-08 |
Th 228+ |
(Sv/h)/(kBq/kg)) |
Playground |
2.84E-07 |
Th 228+ |
(Sv/h)/(kBq/kg)) |
Outdoors, Heap-20 m |
5.35E-08 |
Th 228+ |
(Sv/h)/(kBq/kg)) |
Indoors, Heap-25 m |
6.94E-09 |
Th 228+ |
(Sv/h)/(kBq/kg)) |
Outdoors, on heap 1 m |
3.94E-07 |
Th 228+ |
(Sv/h)/(kBq/kg)) |
House #1, indoors |
5.20E-07 |
Th 228+ |
(Sv/h)/(kBq/kg)) |
House #2, indoors |
4.47E-08 |
Th 230 |
(Sv/h)/(kBq/kg)) |
Playground |
3.69E-11 |
Th 230 |
(Sv/h)/(kBq/kg)) |
Outdoors, Heap-20 m |
5.82E-12 |
Th 230 |
(Sv/h)/(kBq/kg)) |
Indoors, Heap-25 m |
1.11E-14 |
Th 230 |
(Sv/h)/(kBq/kg)) |
Outdoors, on heap 1 m |
3.85E-11 |
Th 230 |
(Sv/h)/(kBq/kg)) |
House #1, indoors |
5.12E-11 |
Th 230 |
(Sv/h)/(kBq/kg)) |
House #2, indoors |
9.41E-12 |
Th 232 |
(Sv/h)/(kBq/kg)) |
Playground |
2.13E-11 |
Th 232 |
(Sv/h)/(kBq/kg)) |
Outdoors, Heap-20 m |
2.21E-12 |
Th 232 |
(Sv/h)/(kBq/kg)) |
Indoors, Heap-25 m |
1.64E-15 |
Th 232 |
(Sv/h)/(kBq/kg)) |
Outdoors, on heap 1 m |
2.23E-11 |
Th 232 |
(Sv/h)/(kBq/kg)) |
House #1, indoors |
3.40E-11 |
Th 232 |
(Sv/h)/(kBq/kg)) |
House #2, indoors |
5.35E-12 |
Th 232sec |
(Sv/h)/(kBq/kg)) |
Playground |
4.62E-07 |
Th 232sec |
(Sv/h)/(kBq/kg)) |
Outdoors, Heap-20 m |
8.19E-08 |
Th 232sec |
(Sv/h)/(kBq/kg)) |
Indoors, Heap-25 m |
8.85E-09 |
Th 232sec |
(Sv/h)/(kBq/kg)) |
Outdoors, on heap 1 m |
6.21E-07 |
Th 232sec |
(Sv/h)/(kBq/kg)) |
House #1, indoors |
8.18E-07 |
Th 232sec |
(Sv/h)/(kBq/kg)) |
House #2, indoors |
7.33E-08 |
U 235+ |
(Sv/h)/(kBq/kg)) |
Playground |
3.29E-08 |
U 235+ |
(Sv/h)/(kBq/kg)) |
Outdoors, Heap-20 m |
3.87E-09 |
U 235+ |
(Sv/h)/(kBq/kg)) |
Indoors, Heap-25 m |
2.11E-11 |
U 235+ |
(Sv/h)/(kBq/kg)) |
Outdoors, on heap 1 m |
3.58E-08 |
U 235+ |
(Sv/h)/(kBq/kg)) |
House #1, indoors |
3.73E-08 |
U 235+ |
(Sv/h)/(kBq/kg)) |
House #2, indoors |
5.42E-09 |
U 235sec |
(Sv/h)/(kBq/kg)) |
Playground |
1.18E-07 |
U 235sec |
(Sv/h)/(kBq/kg)) |
Outdoors, Heap-20 m |
1.45E-08 |
U 235sec |
(Sv/h)/(kBq/kg)) |
Indoors, Heap-25 m |
2.16E-10 |
U 235sec |
(Sv/h)/(kBq/kg)) |
Outdoors, on heap 1 m |
1.33E-07 |
U 235sec |
(Sv/h)/(kBq/kg)) |
House #1, indoors |
1.45E-07 |
U 235sec |
(Sv/h)/(kBq/kg)) |
House #2, indoors |
1.92E-08 |
U 238sec |
(Sv/h)/(kBq/kg)) |
Playground |
3.34E-07 |
U 238sec |
(Sv/h)/(kBq/kg)) |
Outdoors, Heap-20 m |
5.50E-08 |
U 238sec |
(Sv/h)/(kBq/kg)) |
Indoors, Heap-25 m |
4.47E-09 |
U 238sec |
(Sv/h)/(kBq/kg)) |
Outdoors, on heap 1 m |
4.31E-07 |
U 238sec |
(Sv/h)/(kBq/kg)) |
House #1, indoors |
5.67E-07 |
U 238sec |
(Sv/h)/(kBq/kg)) |
House #2, indoors |
5.33E-08 |
U nat |
(Sv/h)/(kBq/kg)) |
Playground |
5.31E-09 |
U nat |
(Sv/h)/(kBq/kg)) |
Outdoors, Heap-20 m |
7.55E-10 |
U nat |
(Sv/h)/(kBq/kg)) |
Indoors, Heap-25 m |
2.96E-11 |
U nat |
(Sv/h)/(kBq/kg)) |
Outdoors, on heap 1 m |
6.23E-09 |
U nat |
(Sv/h)/(kBq/kg)) |
House #1, indoors |
7.47E-09 |
U nat |
(Sv/h)/(kBq/kg)) |
House #2, indoors |
9.49E-10 |
|
|
|
|
|
|
inhalation 線量換算係数(RP-122) |
|
|
|
|
|
核種 |
単位 |
年齢 |
線量換算 |
U 238sec |
Sv/Bq |
<1 |
1.91E-04 |
U nat |
Sv/Bq |
<1 |
6.34E-05 |
Th 230 |
Sv/Bq |
<1 |
4.00E-05 |
Ra 226+ |
Sv/Bq |
<1 |
3.42E-05 |
Pb 210+ |
Sv/Bq |
<1 |
1.84E-05 |
Po 210 |
Sv/Bq |
<1 |
1.80E-05 |
U 235sec |
Sv/Bq |
<1 |
3.95E-04 |
U 235+ |
Sv/Bq |
<1 |
3.00E-05 |
Pa 231 |
Sv/Bq |
<1 |
7.40E-05 |
Ac 227+ |
Sv/Bq |
<1 |
2.91E-04 |
Th 232sec |
Sv/Bq |
<1 |
2.76E-04 |
Th 232 |
Sv/Bq |
<1 |
5.40E-05 |
Ra 228+ |
Sv/Bq |
<1 |
4.91E-05 |
Th 228+ |
Sv/Bq |
<1 |
1.73E-04 |
K 40 |
Sv/Bq |
<1 |
0.00E+00 |
U 238sec |
Sv/Bq |
1-2 |
1.66E-04 |
U nat |
Sv/Bq |
1-2 |
5.52E-05 |
Th 230 |
Sv/Bq |
1-2 |
3.50E-05 |
Ra 226+ |
Sv/Bq |
1-2 |
2.91E-05 |
Pb 210+ |
Sv/Bq |
1-2 |
1.83E-05 |
Po 210 |
Sv/Bq |
1-2 |
1.40E-05 |
U 235sec |
Sv/Bq |
1-2 |
3.49E-04 |
U 235+ |
Sv/Bq |
1-2 |
2.60E-05 |
Pa 231 |
Sv/Bq |
1-2 |
6.90E-05 |
Ac 227+ |
Sv/Bq |
1-2 |
2.54E-04 |
Th 232sec |
Sv/Bq |
1-2 |
2.38E-04 |
Th 232 |
Sv/Bq |
1-2 |
5.00E-05 |
Ra 228+ |
Sv/Bq |
1-2 |
4.81E-05 |
Th 228+ |
Sv/Bq |
1-2 |
1.40E-04 |
K 40 |
Sv/Bq |
1-2 |
0.00E+00 |
U 238sec |
Sv/Bq |
2-7 |
1.09E-04 |
U nat |
Sv/Bq |
2-7 |
3.58E-05 |
Th 230 |
Sv/Bq |
2-7 |
2.40E-05 |
Ra 226+ |
Sv/Bq |
2-7 |
1.91E-05 |
Pb 210+ |
Sv/Bq |
2-7 |
1.12E-05 |
Po 210 |
Sv/Bq |
2-7 |
8.60E-06 |
U 235sec |
Sv/Bq |
2-7 |
2.33E-04 |
U 235+ |
Sv/Bq |
2-7 |
1.70E-05 |
Pa 231 |
Sv/Bq |
2-7 |
5.20E-05 |
Ac 227+ |
Sv/Bq |
2-7 |
1.64E-04 |
Th 232sec |
Sv/Bq |
2-7 |
1.57E-04 |
Th 232 |
Sv/Bq |
2-7 |
3.70E-05 |
Ra 228+ |
Sv/Bq |
2-7 |
3.20E-05 |
Th 228+ |
Sv/Bq |
2-7 |
8.83E-05 |
K 40 |
Sv/Bq |
2-7 |
0.00E+00 |
U 238sec |
Sv/Bq |
7-12 |
7.07E-05 |
U nat |
Sv/Bq |
7-12 |
2.25E-05 |
Th 230 |
Sv/Bq |
7-12 |
1.60E-05 |
Ra 226+ |
Sv/Bq |
7-12 |
1.20E-05 |
Pb 210+ |
Sv/Bq |
7-12 |
7.33E-06 |
Po 210 |
Sv/Bq |
7-12 |
5.90E-06 |
U 235sec |
Sv/Bq |
7-12 |
1.62E-04 |
U 235+ |
Sv/Bq |
7-12 |
1.10E-05 |
Pa 231 |
Sv/Bq |
7-12 |
3.90E-05 |
Ac 227+ |
Sv/Bq |
7-12 |
1.12E-04 |
Th 232sec |
Sv/Bq |
7-12 |
1.06E-04 |
Th 232 |
Sv/Bq |
7-12 |
2.60E-05 |
Ra 228+ |
Sv/Bq |
7-12 |
2.00E-05 |
Th 228+ |
Sv/Bq |
7-12 |
5.97E-05 |
K 40 |
Sv/Bq |
7-12 |
0.00E+00 |
U 238sec |
Sv/Bq |
12-17 |
6.15E-05 |
U nat |
Sv/Bq |
12-17 |
1.91E-05 |
Th 230 |
Sv/Bq |
12-17 |
1.50E-05 |
Ra 226+ |
Sv/Bq |
12-17 |
1.00E-05 |
Pb 210+ |
Sv/Bq |
12-17 |
6.01E-06 |
Po 210 |
Sv/Bq |
12-17 |
5.10E-06 |
U 235sec |
Sv/Bq |
12-17 |
1.45E-04 |
U 235+ |
Sv/Bq |
12-17 |
9.20E-06 |
Pa 231 |
Sv/Bq |
12-17 |
3.60E-05 |
Ac 227+ |
Sv/Bq |
12-17 |
1.00E-04 |
Th 232sec |
Sv/Bq |
12-17 |
9.25E-05 |
Th 232 |
Sv/Bq |
12-17 |
2.50E-05 |
Ra 228+ |
Sv/Bq |
12-17 |
1.60E-05 |
Th 228+ |
Sv/Bq |
12-17 |
5.15E-05 |
K 40 |
Sv/Bq |
12-17 |
0.00E+00 |
U 238sec |
Sv/Bq |
> 17 |
5.70E-05 |
U nat |
Sv/Bq |
> 17 |
1.78E-05 |
Th 230 |
Sv/Bq |
> 17 |
1.40E-05 |
Ra 226+ |
Sv/Bq |
> 17 |
9.53E-06 |
Pb 210+ |
Sv/Bq |
> 17 |
5.69E-06 |
Po 210 |
Sv/Bq |
> 17 |
4.30E-06 |
U 235sec |
Sv/Bq |
> 17 |
1.33E-04 |
U 235+ |
Sv/Bq |
> 17 |
8.50E-06 |
Pa 231 |
Sv/Bq |
> 17 |
3.40E-05 |
Ac 227+ |
Sv/Bq |
> 17 |
9.07E-05 |
Th 232sec |
Sv/Bq |
> 17 |
8.46E-05 |
Th 232 |
Sv/Bq |
> 17 |
2.50E-05 |
Ra 228+ |
Sv/Bq |
> 17 |
1.60E-05 |
Th 228+ |
Sv/Bq |
> 17 |
4.36E-05 |
K 40 |
Sv/Bq |
> 17 |
0.00E+00 |
U 238sec |
Sv/Bq |
worker |
2.91E-05 |
U nat |
Sv/Bq |
worker |
1.28E-05 |
Th 230 |
Sv/Bq |
worker |
7.20E-06 |
Ra 226+ |
Sv/Bq |
worker |
2.23E-06 |
Pb 210+ |
Sv/Bq |
worker |
1.16E-06 |
Po 210 |
Sv/Bq |
worker |
2.20E-06 |
U 235sec |
Sv/Bq |
worker |
8.30E-05 |
U 235+ |
Sv/Bq |
worker |
5.70E-06 |
Pa 231 |
Sv/Bq |
worker |
1.70E-05 |
Ac 227+ |
Sv/Bq |
worker |
6.03E-05 |
Th 232sec |
Sv/Bq |
worker |
4.82E-05 |
Th 232 |
Sv/Bq |
worker |
1.20E-05 |
Ra 228+ |
Sv/Bq |
worker |
1.71E-06 |
Th 228+ |
Sv/Bq |
worker |
3.45E-05 |
K 40 |
Sv/Bq |
worker |
0.00E+00 |
|
|
|
|
|
|
ingestion 線量換算係数(RP-122) |
|
|
|
|
|
核種 |
単位 |
年齢 |
線量換算 |
U 238sec |
Sv/Bq |
<1 |
4.64E-05 |
U nat |
Sv/Bq |
<1 |
7.71E-07 |
Th 230 |
Sv/Bq |
<1 |
4.10E-06 |
Ra 226+ |
Sv/Bq |
<1 |
4.70E-06 |
Pb 210+ |
Sv/Bq |
<1 |
8.42E-06 |
Po 210 |
Sv/Bq |
<1 |
2.60E-05 |
U 235sec |
Sv/Bq |
<1 |
5.20E-05 |
U 235+ |
Sv/Bq |
<1 |
3.54E-07 |
Pa 231 |
Sv/Bq |
<1 |
1.30E-05 |
Ac 227+ |
Sv/Bq |
<1 |
3.86E-05 |
Th 232sec |
Sv/Bq |
<1 |
4.12E-05 |
Th 232 |
Sv/Bq |
<1 |
4.60E-06 |
Ra 228+ |
Sv/Bq |
<1 |
3.00E-05 |
Th 228+ |
Sv/Bq |
<1 |
6.55E-06 |
K 40 |
Sv/Bq |
<1 |
0.00E+00 |
U 238sec |
Sv/Bq |
1-2 |
1.43E-05 |
U nat |
Sv/Bq |
1-2 |
2.84E-07 |
Th 230 |
Sv/Bq |
1-2 |
4.10E-07 |
Ra 226+ |
Sv/Bq |
1-2 |
9.62E-07 |
Pb 210+ |
Sv/Bq |
1-2 |
3.61E-06 |
Po 210 |
Sv/Bq |
1-2 |
8.80E-06 |
U 235sec |
Sv/Bq |
1-2 |
5.70E-06 |
U 235+ |
Sv/Bq |
1-2 |
1.33E-07 |
Pa 231 |
Sv/Bq |
1-2 |
1.30E-06 |
Ac 227+ |
Sv/Bq |
1-2 |
4.27E-06 |
Th 232sec |
Sv/Bq |
1-2 |
7.25E-06 |
Th 232 |
Sv/Bq |
1-2 |
4.50E-07 |
Ra 228+ |
Sv/Bq |
1-2 |
5.70E-06 |
Th 228+ |
Sv/Bq |
1-2 |
1.09E-06 |
K 40 |
Sv/Bq |
1-2 |
0.00E+00 |
U 238sec |
Sv/Bq |
2-7 |
7.90E-06 |
U nat |
Sv/Bq |
2-7 |
1.87E-07 |
Th 230 |
Sv/Bq |
2-7 |
3.10E-07 |
Ra 226+ |
Sv/Bq |
2-7 |
6.21E-07 |
Pb 210+ |
Sv/Bq |
2-7 |
2.20E-06 |
Po 210 |
Sv/Bq |
2-7 |
4.40E-06 |
U 235sec |
Sv/Bq |
2-7 |
4.00E-06 |
U 235+ |
Sv/Bq |
2-7 |
8.62E-08 |
Pa 231 |
Sv/Bq |
2-7 |
1.10E-06 |
Ac 227+ |
Sv/Bq |
2-7 |
2.81E-06 |
Th 232sec |
Sv/Bq |
2-7 |
4.36E-06 |
Th 232 |
Sv/Bq |
2-7 |
3.50E-07 |
Ra 228+ |
Sv/Bq |
2-7 |
3.40E-06 |
Th 228+ |
Sv/Bq |
2-7 |
6.04E-07 |
K 40 |
Sv/Bq |
2-7 |
0.00E+00 |
U 238sec |
Sv/Bq |
7-12 |
5.83E-06 |
U nat |
Sv/Bq |
7-12 |
1.53E-07 |
Th 230 |
Sv/Bq |
7-12 |
2.40E-07 |
Ra 226+ |
Sv/Bq |
7-12 |
8.01E-07 |
Pb 210+ |
Sv/Bq |
7-12 |
1.90E-06 |
Po 210 |
Sv/Bq |
7-12 |
2.60E-06 |
U 235sec |
Sv/Bq |
7-12 |
2.96E-06 |
U 235+ |
Sv/Bq |
7-12 |
7.17E-08 |
Pa 231 |
Sv/Bq |
7-12 |
9.20E-07 |
Ac 227+ |
Sv/Bq |
7-12 |
1.97E-06 |
Th 232sec |
Sv/Bq |
7-12 |
4.62E-06 |
Th 232 |
Sv/Bq |
7-12 |
2.90E-07 |
Ra 228+ |
Sv/Bq |
7-12 |
3.90E-06 |
Th 228+ |
Sv/Bq |
7-12 |
4.31E-07 |
K 40 |
Sv/Bq |
7-12 |
0.00E+00 |
U 238sec |
Sv/Bq |
12-17 |
5.48E-06 |
U nat |
Sv/Bq |
12-17 |
1.49E-07 |
Th 230 |
Sv/Bq |
12-17 |
2.20E-07 |
Ra 226+ |
Sv/Bq |
12-17 |
1.50E-06 |
Pb 210+ |
Sv/Bq |
12-17 |
1.90E-06 |
Po 210 |
Sv/Bq |
12-17 |
1.60E-06 |
U 235sec |
Sv/Bq |
12-17 |
2.46E-06 |
U 235+ |
Sv/Bq |
12-17 |
7.04E-08 |
Pa 231 |
Sv/Bq |
12-17 |
8.00E-07 |
Ac 227+ |
Sv/Bq |
12-17 |
1.59E-06 |
Th 232sec |
Sv/Bq |
12-17 |
5.86E-06 |
Th 232 |
Sv/Bq |
12-17 |
2.50E-07 |
Ra 228+ |
Sv/Bq |
12-17 |
5.30E-06 |
Th 228+ |
Sv/Bq |
12-17 |
3.07E-07 |
K 40 |
Sv/Bq |
12-17 |
0.00E+00 |
U 238sec |
Sv/Bq |
> 17 |
2.57E-06 |
U nat |
Sv/Bq |
> 17 |
1.00E-07 |
Th 230 |
Sv/Bq |
> 17 |
2.10E-07 |
Ra 226+ |
Sv/Bq |
> 17 |
2.80E-07 |
Pb 210+ |
Sv/Bq |
> 17 |
6.91E-07 |
Po 210 |
Sv/Bq |
> 17 |
1.20E-06 |
U 235sec |
Sv/Bq |
> 17 |
1.97E-06 |
U 235+ |
Sv/Bq |
> 17 |
4.73E-08 |
Pa 231 |
Sv/Bq |
> 17 |
7.10E-07 |
Ac 227+ |
Sv/Bq |
> 17 |
1.21E-06 |
Th 232sec |
Sv/Bq |
> 17 |
1.06E-06 |
Th 232 |
Sv/Bq |
> 17 |
2.30E-07 |
Ra 228+ |
Sv/Bq |
> 17 |
6.90E-07 |
Th 228+ |
Sv/Bq |
> 17 |
1.43E-07 |
K 40 |
Sv/Bq |
> 17 |
0.00E+00 |
U 238sec |
Sv/Bq |
worker |
2.57E-06 |
U nat |
Sv/Bq |
worker |
1.00E-07 |
Th 230 |
Sv/Bq |
worker |
2.10E-07 |
Ra 226+ |
Sv/Bq |
worker |
2.80E-07 |
Pb 210+ |
Sv/Bq |
worker |
6.91E-07 |
Po 210 |
Sv/Bq |
worker |
1.20E-06 |
U 235sec |
Sv/Bq |
worker |
1.97E-06 |
U 235+ |
Sv/Bq |
worker |
4.73E-08 |
Pa 231 |
Sv/Bq |
worker |
7.10E-07 |
Ac 227+ |
Sv/Bq |
worker |
1.21E-06 |
Th 232sec |
Sv/Bq |
worker |
1.06E-06 |
Th 232 |
Sv/Bq |
worker |
2.30E-07 |
Ra 228+ |
Sv/Bq |
worker |
6.90E-07 |
Th 228+ |
Sv/Bq |
worker |
1.43E-07 |
K 40 |
Sv/Bq |
worker |
0.00E+00 |
|
|
|
|
|
|
計算式 (RP-122) |
|
|
|
|
|
Eext = Dext × Te × Fd × A (1)
Einh = Dinh × Te × Fd × Br × Cdust × A
(2)
Eing = Ding × Te × Fd × Ring × A (3)
where
Eext, Einh, and Eing are the effective doses due to external gannma radiation,
inhalation, and ingestion exposures (Sv y-1).
Dext, Dinh, and Ding are the dose coefficients for external gannma radiation, inhalation, and ingestion exposures.(Sv h-1 per Bq g-1 for Dext) (Sv Bq-1 for Dinh, and Ding)
Te is the exposure time (y-1)
Fd is
the dilution factor
A is the activity in samples (Bq g-1)
Br is the breathing rate (m3 h-1)
Cdust is the dust concentration during exposure time (g m-3), and
Ring is the ingestion rate (g h-1)
Natural resources such as ore are mainly included U-238 series, Th-232
series and K-40. Therefore, following equations were used to estimate a
total effective dose for workers.
Eext
(total) = Eext (U)+ Eext (Th)+ Eext (K) (4)
Einh (total) = Einh (U)+ Einh
(Th)+ Einh (K) (5)
Eing (total) = Eing (U)+ Eing (Th)+ Eing (K) (6)
Etotal
= Eext (total)+ Einh (total)+ Eing (total) (7)
where
Eext (U), Eext (Th), and Eext (K) are the Eext for U-238 series, Th-232
series, and K-40, respectively. (Sv y-1)
Einh (U), Einh (Th), and Einh (K) are the Einh for U-238 series, Th-232 series, and K-40, respectively. (Sv y-1)
Eing (U), Eing (Th), and Eing (K) are the Eing for U-238 series, Th-232
series, and K-40, respectively. (Sv y-1), and
Etotal is the total effective doses of amount of external gannma radiation,
inhalation, and ingestion exposures due to U-238 series, Th-232 series,
and K-40. (Sv y-1)
参考文献:European commission, Practical use of the concepts of clearance and
ezemption (Part II), EC, Belgium (2002) |
|
|
|
|
|
|
|
|
|
|
|
国立研究開発法人量子科学技術研究開発機構 |
|
Copyright (c) 2007 National Institutes for Quantum Science and Technology. |
|
|
|